MS Oximeter Fingertip Pulse Ped CMS50QA

SKU: 171938

The CMS50QA Pediatric Finger Pulse Oximeter was designed from the ground up to be suitable for children. From the designers of the popular CMS 50B and 50E adult finger pulse oximeter comes the latest offering from Contec Medical Systems. All of the oximeters were specially designed to detect both the pulse rate and blood oxygen saturation level (SPO2).

The CMS50QA was made with a smaller footprint as well as a new software algorithm and sensor that are specifically made with the physical parameters for children. The sensor is calibrated to the thinner skin surface of children, whose skin could be as little as 0.3 inches (8mm). The oximeter opening where one would insert the finger is also specifically miniaturized for pediatric care and pediatric nursing. This helps prevent ambient light from entering the orifice that could cause inaccuracies in the reading. This product is recommended for use on children ages 2 to 13, with a minimum body weight of 35 lbs, or 16 kg. The bright LCD display allows for easy viewing with high contrast.

The most innovative feature in this product is its built-in heartbeat tracker. This auditory blip helps keep track of the heart as its beating without having to look at the display visually. An auditory alarm is also included that would detect when heart rate or SpO2 exceeds a preset specification. This device is intended for sports and/or aviation use only.

PRINT THIS IMAGE

Product Description

Features

  • Ergonomic design without sharp edges to help avoid injury to the child
  • LCD display with multiple display modes
  • Heart beat displayed as bar graph or wave form
  • Auditory alarm for when readings exceed preset specifications
  • Heart beat tracking sound
  • Indicator for low power
  • Automatic shut-off for when no finger is detected

Extended Specifications

  • Measurement of SpO2
  • Measuring range: 0%~99%
  • Accuracy: When the SpO2 measuring range is 70%~99%,the permission of absolute error is ±2%; Below 70% unspecified
  • Measuring range:30bpm~250bpm
  • Accuracy: ±2 bpm or ±2% (select larger)
  • Power supply requirement 3.6 V DC ~ 4.2V DC Rechargeable Battery
  • Resolution SpO2 : 1%, Pulse rate: 1bpm
  • Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%
  • Resistance to surrounding light. The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%

Additional Information

Item #